Response from Climate Plus, LLC:
Thank you so much for the 5-star review, Brian! We're so glad you received excellent service from Climate Plus. If you ever need assistance again, we’re here for all your HVAC needs!
Servicemen on time and always friendly and efficient. While it's never pleasant to spend $$ on a repair, the situation was fully explained to me and I also understand that nothing is inexpensive nowadays. I would recommend your service.
Response from Climate Plus, LLC:
We're glad to hear that our servicemen were on time, friendly, and efficient. We understand that repairs can be costly, but we're pleased that everything was explained clearly to you. Your recommendation means a lot to us. Thank You, Joseph
10-1 Arrival; Customer reporting upstairs unit is out. Pedro was there 7/9 for main: Arrived on site for maintenance. No one was in the building. Someone left unit running, started outside. Washed down condenser. Checked pressures of condenser, Subcooling 12 Superheat 13.4 Unit was a R22 with a txv Low pressure 66 High pressure 173 Was let inside the building. Checked out evaporator coil. Coils are completely rusted. Condensation pan is rusted out. Checked temp split from return and supply duct from directly the air handler. Split peaked at 15 difference. Updated customer on status of unit. Customer acknowledged and signed off.
Arrived on site for no Cooling. Customer turned on the unit when I arrived, the condenser outside was humming loudly. Sound like the the compressor was working but the fan was not spinning. Unplug the disconnect and open up the wiring for the condenser. Check for voltage and amps everything was fine checked out the capacitor that was pretty rusted up on the top but it was fine. Every component was working good except for the fan. Notice that the fan has a thermal protection, rang up the hose and tried calling it down for about 5 minutes with water.
Arrived on site for no Cooling. Customer turned on the unit when I arrived, the condenser outside was humming loudly. Sound like the the compressor was working but the fan was not spinning. Unplug the disconnect and open up the wiring for the condenser. Check for voltage and amps everything was fine checked out the capacitor that was pretty rusted up on the top but it was fine. Every component was working good except for the fan. Notice that the fan has a thermal protection, rang up the hose and tried calling it down for about 5 minutes with water. At the cooling down the condenser turned on the connector by plugging in the disconnect and the unit turned on very loudly. Check for pressures and pressures were pretty low super heat was higher than 50 and what temperature difference inside the house Peak at four degrees difference.
UV Light Air Purification Installation: Installed a UV-C germicidal light system inside the HVAC air handler to neutralize airborne pathogens. Connected the unit to the blower control circuit, ensuring it operated only during air circulation, and verified UV output for indoor air quality improvement.
Arrived onsite for ac maintenance on 1 system. Homeowner mentioned noise from indoor blower fan. Could not recreate the noise. System worked well while there. . Checked all electrical. Chemically Cleaned outside coil. measured pressures for 410a at 120/245psi with 5 degree sub cooling with outside temperature at 81 degrees. Measured temperature drop at 17 degrees. Cleaned out condensate line. Removed 20x20x1 filter located in air handler. Installed 2 -14x28x1 filters in filter grill provided by the homeowner System running as it should.
Arrived on site for maintenance. No one was in the building. Someone left unit running, started outside. Washed down condenser. Checked pressures of condenser,
Arrived onsite for no cooling call. Performed diagnostic on the system. Found a fault in the voltage enhancement system. Inspected motors and they seem to be in working order. Performed gold repair for the voltage enhancement system. System running as it should. Measured 30 degree temperature drop. Did not observe strange noises. Pressure within line of manufacturer’s settings. Confirmed filter is in good shape.
customer experiencing unit slowing down and not cooling well it is around 15 years old and so is the furnace. He is interested in replacing, well aware that may be a possibility.
Received a call at the AC system was not operating, upon arrival I found that the unit was running but low on refrigerant. It is an older R22 system and I do not recommend leak testing at this time. Added 3 lb of R22 refrigerant and the unit is now operating and cooling properly.
Arrived on site for no cooling call. Condenser fan was running. Air handler was running Compressor was off. Checked/tested capacitor. Capacitor was dead. Replaced capacitor. Compressor and condenser was fully operational. Updated customer. Customer acknowledged and signed off.
Heating System Repair: Diagnosed a cracked heat exchanger that posed a safety hazard. Removed and installed a new exchanger, ensuring proper combustion and restoring safe, efficient heat output.
Seasonal maintenance for (1) split system up to 5 ton cooling capacity, either roof or ground mounted Includes replacing of standard fiberglass air filter (pleated higher performance filters can be added at an additional cost) , includes replacing blower belt (if applicable), grease or oil bearings, chemically clean the condensing unit, clean the condensate drain line, check operation of all safety devices, check operation of operating controls, check all motors, compressor and refrigerant charge, visual inspection of the duct system. With a Comfort Club service you will also receive the added benefits of a 10% discount on repairs and diagnostic fees, service within 48 hours of placing the call and a water heater flush
Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, measured pressures for 410a at 125/265psi with 10 degree sub cooling with outside temperature at 72 degrees. Measured temperature drop at 20 degrees. Cleaned condensate line. changed 20x30x1 filter. Performed efficiency test utilizing MeasureQuick. System running as it should.
HVAC Repair: Upgraded an outdated thermostat with a modern programmable unit, allowing for better temperature scheduling and improved energy management.