5558 Berkshire Valley Road STE 6
Oak Ridge, NJ 07438
(973) 838-3200

Our Top Cities


Local Reviews
for fair lawn, nj

Rated 5.0 out of 5 stars based on 3 customer reviews

Excellent service


Response from Climate Plus, LLC:

Thank you so much for the 5-star review, Brian! We're so glad you received excellent service from Climate Plus. If you ever need assistance again, we’re here for all your HVAC needs!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very pleased with service.

Servicemen on time and always friendly and efficient. While it's never pleasant to spend $$ on a repair, the situation was fully explained to me and I also understand that nothing is inexpensive nowadays. I would recommend your service.


Response from Climate Plus, LLC:

We're glad to hear that our servicemen were on time, friendly, and efficient. We understand that repairs can be costly, but we're pleased that everything was explained clearly to you. Your recommendation means a lot to us. Thank You, Joseph

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Happy

Excellent communication as well as service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fair lawn, nj

Gianna M.

Gianna M. Job Checkin

Heating System Repair: Diagnosed a cracked heat exchanger that posed a safety hazard. Removed and installed a new exchanger, ensuring proper combustion and restoring safe, efficient heat output.


Gianna M.

Gianna M. Job Checkin

UV bulb replacement.

UV bulb replacement.

Gianna M.

Gianna M. Job Checkin

Seasonal maintenance for (1) split system up to 5 ton cooling capacity, either roof or ground mounted Includes replacing of standard fiberglass air filter (pleated higher performance filters can be added at an additional cost) , includes replacing blower belt (if applicable), grease or oil bearings, chemically clean the condensing unit, clean the condensate drain line, check operation of all safety devices, check operation of operating controls, check all motors, compressor and refrigerant charge, visual inspection of the duct system. With a Comfort Club service you will also receive the added benefits of a 10% discount on repairs and diagnostic fees, service within 48 hours of placing the call and a water heater flush

Seasonal maintenance for (1) split system up to 5 ton cooling capacity, either roof or ground mounted
Includes replacing of standard fiberglass air filter (pleated higher performance filters can be added at an additional cost) , includes replacing blower belt (if applicable), grease or oil bearings, chemically clean the condensing unit, clean the condensate drain line, check operation of all safety devices, check operation of operating controls, check all motors, compressor and refrigerant charge, visual inspection of the duct system. With a Comfort Club service you will also receive the added benefits of a 10% discount on repairs and diagnostic fees, service within 48 hours of placing the call and a water heater flush

Gianna M.

Gianna M. Job Checkin

Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, measured pressures for 410a at 125/265psi with 10 degree sub cooling with outside temperature at 72 degrees. Measured temperature drop at 20 degrees. Cleaned condensate line. changed 20x30x1 filter. Performed efficiency test utilizing MeasureQuick. System running as it should.

Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, measured pressures for 410a at 125/265psi with 10 degree sub cooling with outside temperature at 72 degrees. Measured temperature drop at 20 degrees. Cleaned condensate line. changed 20x30x1 filter. Performed efficiency test utilizing MeasureQuick. System running as it should.

Gerard E.

Gerard E. Job Checkin

HVAC Repair: Upgraded an outdated thermostat with a modern programmable unit, allowing for better temperature scheduling and improved energy management.


Jack B.

Jack B. Job Checkin

Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, removed debris, cleared drainage holes. Observed a rusting in the outside condenser, measured pressures for R22 at 48/120psi with 17 degree sub cooling with outside temperature at 60degrees. Observed the suction line icing up. Cleaned evaporator coil and blew out condensate line. Observed significant rusting on the evaporator coil. Observed more icing on the inside coil. Recommend upgrading the system based on age and condition of the system.

Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Checked all electrical. Chemically Cleaned outside unit, removed debris, cleared drainage holes. Observed a rusting in the outside condenser, measured pressures for R22 at 48/120psi with 17 degree sub cooling with outside temperature at 60degrees. Observed the suction line icing up. Cleaned evaporator coil and blew out condensate line. Observed significant rusting on the evaporator coil. Observed more icing on the inside coil. Recommend upgrading the system based on age and condition of the system.

Jack B.

Jack B. Job Checkin

Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Homeowner will changed filter in ceiling. No longer using 213 filter media. Checked all electrical. Chemically Cleaned outside unit removed debris and VMware’s drainage holes. measured pressures for 410a at 111/206psi with 10degree sub cooling with outside temperature at 60 degrees. Measured temperature drop at 18.5 degrees. Cleaned evaporator coil and cleared condensate line. System running as it should.

Arrived onsite for ac maintenance on 1 units. Asked customer to turn AC on to confirm operation. Homeowner will changed filter in ceiling. No longer using 213 filter media. Checked all electrical. Chemically Cleaned outside unit removed debris and VMware’s drainage holes. measured pressures for 410a at 111/206psi with 10degree sub cooling with outside temperature at 60 degrees. Measured temperature drop at 18.5 degrees. Cleaned evaporator coil and cleared condensate line. System running as it should.

Jack B.

Jack B. Job Checkin

Arrived onsite for ac maintenance on 1 system. Turn AC on to confirm operation. Checked all electrical. Removed condenser top and clear debris. Chemically Cleaned outside coils and cleared drain holes, measured pressures for R407c at 47/101psi with 1.4 degree sub cooling with outside temperature at 48 degrees. Measured temperature drop at 21 degrees. Cleaned evaporator coil and condensate line. Changed 213 media filter provided by Climate Plus. System running as it should.

Arrived onsite for ac maintenance on 1 system. Turn AC on to confirm operation. Checked all electrical. Removed condenser top and clear debris. Chemically Cleaned outside coils and cleared drain holes, measured pressures for R407c at 47/101psi with 1.4 degree sub cooling with outside temperature at 48 degrees. Measured temperature drop at 21 degrees. Cleaned evaporator coil and condensate line. Changed 213 media filter provided by Climate Plus. System running as it should.

Steven M.

Steven M. Job Checkin

HVAC Repairs: Upon inspecting a client’s HVAC system, I discovered damaged insulation on the electrical wiring, posing both safety and performance concerns. I promptly replaced the compromised insulation to restore safe and efficient system operation.


Gerard E.

Gerard E. Job Checkin

Removed old boiler installed new crown velocity boiler. Installed four new zones plus an indirect tank was existing. Piped in indirect tank the proper way on auxiliary. Installed magna clean, expansion tank, spiral vent, Purge setup, with three separate circulator pumps. Pumps also included four zone valves. Everything is isolated and operating at this time. Ran 2-in PVC outside vented proper distances from Windows and doors.


Jack B.

Jack B. Job Checkin

Arrived onsite for heating maintenance 2 gas fired furnaces 1 in basement and 1 in the attic. Attic Furnace System: Turn heat on and confirmed operation. Changed 14x24x1 filter provided by customer. Brushed and Wiped down furnance blower cabinet and gas burners. Burners fired and are in good working order. No visual impingement detected. Checked electrical. Cleaned the flame sensor.. Measure temperature rise at 42 degrees. Performed Combustion Test. System is operating as it should. Discuss replacement of basement system as it is near 20 years and has used over 95% of its life expectancy. Homeowner would like to wait a couple more years.

Arrived onsite for heating maintenance 2 gas fired furnaces 1 in basement and 1 in the attic.

Attic Furnace System: Turn heat on and confirmed operation. Changed 14x24x1 filter provided by customer.
Brushed and Wiped down furnance blower cabinet and gas burners. Burners fired and are in good working order. No visual impingement detected. Checked electrical. Cleaned the flame sensor.. Measure temperature rise at 42 degrees. Performed Combustion Test. System is operating as it should. Discuss replacement of basement system as it is near 20 years and has used over 95% of its life expectancy. Homeowner would like to wait a couple more years.

Jack B.

Jack B. Job Checkin

Arrived onsite for maintenance on 4 systems. Performed inspection of the performance, mechanical, and safety systems. Started in suite 202. Confirmed operation of all systems. Cleaned washable filters on 3 mini split cassettes. Changed 20x20x1 ceiling filter. Measured temperature drop of 20 degrees on the big unit. 23 degrees in the small unit. 17 degrees on the ceiling split system.

Arrived onsite for maintenance on 4 systems. Performed inspection of the performance, mechanical, and safety systems. Started in suite 202. Confirmed operation of all systems. Cleaned washable filters on 3 mini split cassettes. Changed 20x20x1 ceiling filter. Measured temperature drop of 20 degrees on the big unit. 23 degrees in the small unit. 17 degrees on the ceiling split system.

Jack B.

Jack B. Job Checkin

3/7/25 Arrived onsite for no heating on a gas fired boiler with 2 zones. Performed diagnostic and found the fault in the control system where it was not recognizing the draft damper is open. The plug receptor would not properly connect. Attempted to make a better connection but could not. Recommend replacing aquastat relay. Customer agreed to repair and signed up for elite partner plan. 3/8/25 performed repair and confirmed operation of the boiler Looked at failed AC system. Found rodent nest but did not observe chewed wires. Homeowner would like an estimate for replacement of the AC; or may like to try to fix the system.

3/7/25 Arrived onsite for no heating on a gas fired boiler with 2 zones. Performed diagnostic and found the fault in the control system where it was not recognizing the draft damper is open. The plug receptor would not properly connect. Attempted to make a better connection but could not. Recommend replacing aquastat relay. Customer agreed to repair and signed up for elite partner plan. 3/8/25 performed repair and confirmed operation of the boiler Looked at failed AC system. Found rodent nest but did not observe chewed wires. Homeowner would like an estimate for replacement of the AC; or may like to try to fix the system.

Jack B.

Jack B. Job Checkin

Arrived onsite for continue diagnostic on mini split error code. Upon arrival customer explained that the error code cleared itself. Performed diagnostic but did not find an issue. If problem happens again we can attempt to trouble shoot with tech support when the error code is present.


Jack B.

Jack B. Job Checkin

Arrived onsite for fujistu mini split not working. Received error code. Performed diagnostic utilizing Fujitsu technician support. Found possible fault in control boards. Will perform further diagnostic on inside unit to confirm which boards are affected. Scheduled return visit for March 4th 5pm.

Arrived onsite for fujistu mini split not working. Received error code. Performed diagnostic utilizing Fujitsu technician support. Found possible fault in control boards. Will perform further diagnostic on inside unit to confirm which boards are affected. Scheduled return visit for March 4th 5pm.